Insulation calculator
Bags of batts or rolls of insulation for walls, attics and lofts, in the pack sizes sold where you live.
How it works
Measure the area you're insulating: the wall (length × height), the attic or loft floor (length × width), or the floor over a crawl space. Take off doors and windows in a wall. Then divide by the coverage printed on the pack and round up. That coverage is the area of wall or ceiling one pack fills, with the batts sized to sit between standard stud or joist spacing, so there's no need to take the framing off.
For two layers, such as batts between the joists and a second layer across them, each layer needs its own packs for the same area. We add the R-values (or, in the UK, the thicknesses) so you can see the total.
Worked examples
A US wall: 30 ft long and 8 ft high, less a 36 sq ft window and door, is 204 sq ft. R-13 batts at 106.56 sq ft a bag: 2 bags.
A US attic: 40 × 25 ft is 1,000 sq ft. Two layers of R-19 (R-38 in all) at 77.5 sq ft a bag need 13 bags per layer, 26 in all; R-38 attic batts at 64 sq ft a bag need 16 bags.
A Canadian basement wall: 10 m long and 2.44 m high, less 3 m² of windows, is 21.4 m². R-20 batts covering 78.3 sq ft (7.27 m²) a bag: 3 bags.
A UK loft: 8 × 5 m is 40 m². A 100 mm layer between the joists at 11.08 m² a roll needs 4 rolls, and a 170 mm layer across them at 6.47 m² a roll needs 7: 270 mm in all, the depth the Energy Saving Trust recommends.
An Australian ceiling: 12 × 10 m is 120 m². R4.1 ceiling batts at 5.6 m² a pack: 22 packs.
How much insulation you need
- US: Energy Star's recommended levels for an existing home depend on your climate zone. For an uninsulated attic, it lists R30 in zone 1, R49 in zones 2 and 3, and R60 in zones 4 to 8. If you already have 3 to 4 inches, R25 to R49 on top. For floors, R13 to R38.
- UK: the Energy Saving Trust recommends at least 270 mm of loft insulation. Wickes suggests 100 mm between the joists and 170 mm across them; more is better.
- Canada and Australia: the levels are set by your provincial building code (Canada) or your climate zone in the National Construction Code (Australia). Check with your local building authority or the retailer.
Before you start
Don't squash batts to fit: compressed insulation loses some of its R-value. Keep insulation clear of recessed lights and flues unless they're rated for contact, and leave gaps at the eaves so the roof space can breathe. Wear gloves, long sleeves and a dust mask when handling glass wool. If you're putting up drywall or plasterboard over insulated walls, the drywall calculator works out the sheets.
Sources
- Energy Star: recommended home insulation R-values
- Energy Saving Trust: how to insulate a loft (at least 270 mm)
- Wickes: insulating your loft (100 mm + 170 mm; roll coverages)
- Pack coverages: Home Depot R-13, Home Depot R-19, Lowe's R-38, Kent R-12, Kent R-20, Kent R-40, Wickes 200 mm, Bunnings R2.0, Bunnings R4.1, Bunnings R5.0
Common questions
How many bags of insulation do I need?
Divide the area by the coverage on the bag and round up. A 1,000 sq ft attic with R-38 attic batts at 64 sq ft a bag needs 16 bags; a 30 × 8 ft wall (less a 36 sq ft opening) with R-13 batts at 106.56 sq ft a bag needs 2.
Do I subtract the studs when working out insulation?
No. Batt coverage on the pack is the area of wall or ceiling it fills, already allowing for the studs or joists between the batts.
How much loft insulation do I need in the UK?
At least 270 mm, according to the Energy Saving Trust: usually 100 mm between the joists and 170 mm across them. A 40 m² loft needs 4 rolls of 100 mm (11.08 m² each) and 7 rolls of 170 mm (6.47 m² each).
What R-value do I need in my attic?
In the US it depends on your climate zone. Energy Star recommends R30 to R60 for an uninsulated attic, and R25 to R49 on top of 3 to 4 inches already there. In Canada and Australia, check your local building code.
Can I lay a second layer of insulation on top?
Yes. Lay the second layer across the joists, at right angles to the first, so it covers the tops of the joists. R-values of layers add up: two layers of R-19 make R-38.
Reviewed by Alex Rowan, Editor. Last reviewed . How we calculate · Report a problem